Research Symposium
25th annual Undergraduate Research Symposium, April 1, 2025
Imanol Lopez Poster Session 1: 9:30 am - 10:30 am/ Poster #99

BIO
My name is Imanol Lopez, I am 20 years old and double majoring in Biology and Public Health at Florida State University. I have passionate interests in the research community specifically regarding regenerative medicine and epidemiology. I find it quite fascinating how microscopic living organisms influence our overall well-being and aspire to pursue such doctrines to attain a better comprehension that would ultimately allow us to better care for our communities in a more efficient manner. I hope to one day work at the Center for Disease Control and Prevention (CDC) conducting research beneficial to humanity in combating the everlasting presence of pestilence.
Cationic Partitioning Indicator Displacement Assay
Authors: Imanol Lopez, Dr. Steven LenhertStudent Major: Biology, Public Health
Mentor: Dr. Steven Lenhert
Mentor's Department: Department of Biological Sciences Mentor's College: College of Arts and Sciences Co-Presenters: Henry Amador
Abstract
Indicator Displacement Assays (IDAs) are a form of molecular detection used across multiple disciplines for their convenience and effectiveness. Cost efficient and easy to manipulate these sensors can detect small molecules such as pollutants and dyes. Recent research has resulted in the creation of an IDA using a two-phase system that results in the analyte partitioning into an organic oil droplet. To improve upon and alter the previous design, we chose to investigate the effects of droplets size on displacement rate, as well as its ability to detect cationic salts. A solution of oleic acid and methylene blue dye were printed on a slide and later flowed with varying salts. Absorbance data was collected using ImageJ to assess droplet selectivity through displacement/partitioning which determined copper and lead had a higher preference for oleic acid, displacing the blue dye. For the droplet size experiment, the same solution of oleic acid and methylene blue dye was utilized to print droplets of varying proportions onto a slide which was later flowed with an acidic solution. Droplet sizes were analyzed before and after the flow, and absorbance of data was collected similarly to the previous experiment. Analysis demonstrates smaller sized droplets improved the sensitivity of the droplet. Further sensor alteration could lead to specific detection of metallic ions based on droplet composition. If explored further, the implications for this system to be used as a replacement for current methods of water quality testing which remain expensive, insensitive, and not widely available.
Keywords: Biology, Chemistry, Indicator Displacement Assay